"chromium replating on uses cold draw punches"
Question:
"What chemical should be used for removing passivation layer on chrome plated used punches to replate them properly"
Answer:
A common solution annealing temperature for 316SS is approximately 1950F. It is difficult to answer your question regarding the need to passivate after solution annealing, based on lack of knowledge regarding specification and customer requirements.